show facility-alarm status. Depending on the type of alarms you configure, you might see. show facility-alarm status

 
 Depending on the type of alarms you configure, you might seeshow facility-alarm status  10

Mark as New;For the latest feature information and caveats, see the release notes for your platform and software release. You can connect an external alarm, such as a buzzer or light, to the alarm output interface. Severity. show facility-alarm relay. Use the command "show platform" €or €"show facility-alarm status" to determine status of Fans in the Tray. Sends power supply alarm traps to a syslog server. > show facility-alarm status info Source Severity Description Relay Time firepower minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 firepower minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 firepower major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. pemasirid. show env power . Step 5 . Displays all global alarm settings on the switch. Note: To clear the the alarm LED, you need to shutdown the ports which are not connected. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. end. show environment alarm-contact. The documentation set for this product strives to use bias-free language. Alarms. Step 8. 显示输入报警触点的物理状态信息。 show facility-alarm relay. For the latest feature information and caveats, see the release notes for your platform and software release. For the latest feature information and caveats, see the release notes for your platform and software release. Verifying Normal Startup Sequence. 1 Accepted Solution Arshad Safrulla VIP Options 07-26-2021 07:05 AM You can issue the below command to check why the error is there show facility-alarms statusThe facility-alarm critical exceed-action shutdown command is disabled on the Cisco ASR 1001-X Router. Check for the following o/p: show facility-alarm status GigabitEthernet0/0/0 CRITICAL Physical Port Link Down [1] GigabitEthernet0/0/2 CRITICAL Physical Port Link Down [1] See if you have any ports down or if it says CRITICAL anywhere in the above. alarm facility power-supply syslog. •show environment power •show platform hardware slot P <0-5> mcu status •show facility-alarm status •show redundancy •show redundancy line card all •show ip ospf neighbor •show cable modem voice •show cable calls •show cable licenses all •show inventory •show log •show cable rpd •show cable modem summary total •show cable. Depending on the type of alarms you configure, you might see. Effective from Cisco IOS XE Everest 16. The following are examples of alarm messages that are sent to the console. •show facility-alarm status [info |major |minor] AlarmsfortheCiscoISA3000 6 AlarmsfortheCiscoISA3000 MonitoringAlarms. We disabled the g0/0/5 interface , in addittion on this interface there was not a connected sfp. show alarm settings. Examples of Alarm Messages. 11. 11. Depending on the type of alarms you configure, you might see. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index]----- ----- ----- -----subslot 0/0 May 18 2016 14:50:49 CRITICAL Active Card Removed OIR Alarm [0] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1]. Verifies the. You can limit the view by filtering on major or minor status. Verify the configuration. For the latest feature information and caveats, see the release notes for your platform and software release. show environment alarm-contact. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Displays the switch power status. end. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Title: Alarms for the Cisco ISA 3000Bias-Free Language. Displays all generated alarms for the switch. The default severity level is informational, which shows all alarms. Network administrators do not need to use show commands to poll devices on a routine basis and can monitor the network remotely. Router# show facility-alarm status. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Router# show facility-alarm status critical System Totals Critical: 5 Major: 0 Minor: 0 Source Severity Description [Index]. There is no such behavior documented . You can limit the view by filtering on major or minor status. Router(config)# logging alarm critical. Verifying Normal Startup Sequence. For the latest feature information and caveats, see the release notes for your platform and software release. Displays all global alarm settings on the switch. To view the alarms on Cisco ASR 1001 router, use the show facility-alarm status command. Facility Protocol Status Support; Monitoring Alarms. ez9. When I create a Tag Alarm and Event Server and double click on the. show redundancy line card all. show facility-alarm relay. Clearing Specific Alarms and EventsFacility Protocol Status Support; Monitoring Alarms. Description [Index]:You can view these alarms using the show facility alarm status command. Effective from Cisco IOS XE Everest 16. ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored. To save user time and effort, it supports changeable alarm configurations by using alarm profiles. Displays all generated alarms for the switch. Theseverity controlsthebehavioroftheLEDassociatedwiththecontact. 10. Theseverity controlsthebehavioroftheLEDassociatedwiththecontact. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored but the power supply state remains in OK state as the. show environment alarm-contact. You can verify the alarms that cause the LED to. How to Configure Switch Alarms Configuring the Switch Temperature Alarms Associating the Temperature Alarms to a Relay By default, the primary temperature alarm is. Managing Alarms via the MIB. show env power. See the Cisco 10000 Series ESR Troubleshooting Guide. However, network administrators can perform onsite. System Totals Critical: 22 Major: 0 Minor: 0. Table 5-1 Switch Global Status Monitoring Alarms FCS Error Hy. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. show facility-alarm status —Displays the alarms status attached to a specific profile. Monitoring Syslog Messages for Alarms. I have attached a show ip int bri & show facility-alarm status since it is more user. Monitoring >Properties >Alarm >Facility Alarm Status AlarmportssupportfortheISA3000 9. 1 Accepted Solution Arshad Safrulla VIP Options 07-26-2021 07:05 AM You can issue the below command to check why the error is there show facility-alarms status TodisplaythetriggeredalarmsinanISA3000device,usetheshow facility-alarm commandinuserEXEC mode. Alarms. Go to solution. Verifying Normal Startup Sequence. The info keyword provides the same output as using no keyword. Thanks for your help. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Shows the current configuration for each possible alarm. Router# show facility-alarm status | inc 0/3/0 t1 0/3/0 Feb 01 2018 19:23:10 CRITICAL Section Receiver has loss of signal [1] Verifying Alarm Profile for Severity Change for T1 or E1 Alarms; Verifying Alarm Profile for. Step 6 . The following are examples of alarm messages that are sent to the console. Related Documents. CONTENTS CHAPTER 1 Feature History 1 CHAPTER 2 Alarms 3 SONETAlarms 3 SDHAlarm 3 CHAPTER 3 Alarm Profiling and Auto In-Service States 7 AlarmProfiling 7 LimitationsofAlarmProfiles 8 AlarmProfileClassification 9 AlarmSupportforLoopback 12 DefaultAlarmProfiles 12 HowtoConfigureAlarmProfile 12 CreatingAlarmProfile 12. show facility-alarm status. For the latest feature information and caveats, see the release notes for your platform and software release. show facility-alarm statusコマンドを使用して、LED. You can limit the view by filtering on major or minor status. The clear facility-alarm command does not clear an alarm LED on the . 显示每个可能的报警的当前配置。 show environment alarm-contact. 2 Beforeproceedingwiththeupgradingordowngradingoperation,beawarethattheversionsofCiscocBR-8 routerand2x2RPDmustbecompatible. Time-----Severity-----May 18 2016 14:50:49 CRITICAL. The following example shows how to use the show facility-alarm status command to verify if any critical alarm is generated when a module is removed from the system: Device# show facility-alarm status System Totals Critical: 8 Major: 0. See the Cisco 10000 Series ESR Troubleshooting Guide. 6. show facility-alarm status Displays all generated alarms for the switch. Monitoring >Properties >Alarm > Facility Alarm Status AlarmportssupportfortheISA3000 9. Then I would try to use different port. Alarm Yellow Off Indicates an alarm condition at OC-12, DS3, or DS1 level. Send power supply alarm traps to an SNMP server. end. The LEDs indicate all system states in the startup sequence. Verify the configuration. show facility-alarm status [info | major | minor] 12-02-2021 06:22 AM. alarm facility power-supply syslog. To view alarms, use the show facility-alarm status command. The clear facility-alarm command does not clear an alarm LED on the Cisco Catalyst 9800-40 Wireless Controller. On the ASR 1000 chassis that uses the affected Cisco IOS XE images (see the Products Affected section), the PSU state might be incorrectly displayed as “ps fail” even though the PSU functions as intended. For the latest feature information and caveats, see the release notes for your platform and software release. The following are examples of alarm messages that are sent to the console. show facility-alarm status [info | major | minor] Alarm Output Interface. The allowable range is from 1 to 10 percent. Depending on the type of alarms you configure, you might see. Loop (active loop) Yellow Off Port is in a loopback stat e and not enabled for data traffic. show facility-alarm status [info | major | minor] This command displays all alarms based on severity specified. •major. ASR903#show platform | in FAN|State Chassis type: ASR-903 Slot Type State Insert time (ago)Insteadofconfiguringonecontact,youcanspecifyanytochangetheseverityforallcontacts. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Alarm support is intended to cover a focused subset of router states that are likely to indicate service impacts (or imminent service impacts) related to the overall state of hardware assemblies (cards, fans, links, and so on). show facility-alarm status GigabitEthernet0/0/0 CRITICAL Physical Port Link Down [1] GigabitEthernet0/0/2 CRITICAL Physical Port Link Down [1] See if you have any ports down or if it says CRITICAL anywhere in the above o/p. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. show facility-alarm status. Switch#show facility-alarm status Source Severity Description Relay Time Switch MINOR 34 HSR ring is partially down MAJ Oct 24 2017 10:16:10 ----- Switch# show facility-alarm status Source Severity Description. 1 AS 1670. The LEDs indicate all system states in the startup sequence. 下這個指令查詢錯誤訊息,show facility-alarm status 請參考這幾篇文章。 好的,感谢 clear facility-alarm. Source Severity Description [Index]----- ----- -----subslot 0/0 CRITICAL Active Card Removed OIR Alarm [0] Is there any way I can remove this Alarm, I dont want to reboot ASR and I already run clear facility-Alarm command. The State column in show platform command output should display "ok" for SIPs, SPAs,. Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index]----- ----- ----- -----subslot 0/0 May 18 2016 14:50:49 CRITICAL Active Card Removed OIR Alarm [0] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1]. Monitoring >Properties >Alarm >Facility Alarm Status AlarmportssupportfortheISA3000 9. show facility-alarm status —Displays the alarms status attached to a specific profile. Source-----subslot 0/0. show env {all | power | temperature} Displays the status of environmental facilities on the switch. Use the show platform and show environment all commands to check the online and environmental status of each FRU after installation. You can view the SNMP traps through the SNMP manager. end. Command or Action Purpose Step 1 enable Example: Router> enable. Step 6 . Router# show facility-alarm status. Additionally, you can use the show facility-alarm status command to view the alarms. Verifying Normal Startup Sequence. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. Source Shows the system component that is the source of the alarm. show facility. Title: Alarms for the Cisco ISA 3000Router#show fa Router#show facility-alarm % Incomplete command. The following example. show cable modem summary total. Because that could also mean RMA for the box. end. All alarms and. For the latest feature information and caveats, see the release notes for your platform and software release. Theseverity controlsthebehavioroftheLEDassociatedwiththecontact. Displays all generated alarms for the switch. show alarm settings. Send power supply alarm traps to a syslog server. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. Alarms. The following are examples of alarm messages that are sent to the console. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. • show facility-alarm status コマンドを入力します。次の例は、正規の手順で SPA を非アクティブにせずにアクティブ SPA を取り外したために生成されたクリティカル アラームを示しています。 次に、 show facility-alarm relay コマンドの出力例を示します。 ciscoasa> show facility-alarm relay Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 . Alarms. Cisco IOS プロセスのリソース. To clear the the alarm LED, you need to shutdown the ports which are not connected. For the latest feature information and caveats, see the release notes for your platform and software release. Shows information about the alarms that have triggered the output relay. Displaying the List of Current Active Alarms and Events. Configuring the Power Supply Alarms. Alarms. Step 7 . alarm facility power-supply syslog. Network administrators do not need to use show commands to poll devices on a routine basis and can monitor the network remotely. show alarm settings. Step 10 . As. The following. Facility Protocol Status Support; Monitoring Alarms. show facility-alarm status. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Verifying Normal Startup Sequence. Router# show facility-alarm status System Totals Critical: 2 Major: 0 Minor:. show facility-alarm {relay | status [info | major | minor]} SyntaxDescription relay Displays thealarmsthathaveenergized alarmoutputrelay. Step 7 . Severity. Alarms. Monitoring Syslog Messages for Alarms. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Network administrators do not need to use show commands to poll devices on a routine basis and can monitor the network remotely. The LEDs indicate all system states in the startup sequence. Source. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. The following example shows alarm status for minor and major HSR alarms: Switch#show facility-alarm status. Step 10 show alarm settings Verifies the configuration. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. show alarm profile [name] Displays all alarm profiles in the system or a specified profile. For the latest feature information and caveats, see the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Switch#show facility-alarm status Source Severity Description Relay Time Switch MINOR 34 HSR ring is partially down MAJ Oct 24 2017 10:16:10 ----- Switch# show facility-alarm status Source Severity Description Relay Time Switch MAJOR 33 HSR ring. You can limit the view by filtering on major or minor status. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. copy running-config startup-configForexample,toenableallactionsforthealarminputcontact1,enterthefollowing: alarmfacilityinput-alarm1relay alarmfacilityinput-alarm1syslog alarmfacilityinput-alarm1notifiesIf you want to know why one of these facility LEDs is lit, the appropriate command is “show facility-alarm status”. You can connect an external alarm, such as a buzzer or light, to the alarm output interface. The info keyword provides the same output as using no keyword. Hello, I have a Cisco ASR 1006-X that I cant seem to get the crit led light to go off, I have been under the impression that interfaces that are down, down vs being admin down would cause this but all my interfaces are up, up or admin down. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. Monitoring Syslog Messages for Alarms. end. The example shows a critical alarm for Power supply along with the. show env {all | power | temperature} Displays the status of environmental facilities on the switch. Source Severity Description [Index] GigabitEthernet0/0/0 INFO Physical Port Administrative State Down [2]. alarm facility power-supply notifies. The output displays the following information: Column. end. The example shows a critical alarm for Power supply along with the description: SPA Removed. Trying to bring up an ISR4331 that has 2 - LTE cards installed in it. show log. Verifying Normal Startup Sequence. Step 11 copy running-config startup-config (Optional) Saves your entries in the configuration file. My c9800-40 pair always shows and Red (Amber) Alarm led on the active unit. The routers are designed to send alarm notifications when problems are detected. Router# show facility-alarm status System Totals Critical: 18 Major: 0 Minor:. Effective from Cisco IOS XE Everest 16. CLI display (show routines) allows the system operator to easily identify current facility alarm conditions and recently cleared alarms without searching event logs or monitoring various card and port show commands to. Yellow. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. The info keyword provides the same output as using no keyword. Step 4 . You can connect an external alarm, such as a buzzer or light, to the alarm output interface. Voltage Fornormaloperation,onlyonepowerfeed(A900-PWR900-D2)issufficientbutanalarmisgeneratedifonly onepowerfeedispresent. For the latest feature information and caveats, see the release notes for your platform and software release. Monitoring >Properties >Alarm > Facility Alarm Status AlarmportssupportfortheISA3000 9. The LEDs indicate all system states in the startup sequence. show redundancy. ALARMS For Cisco ASR 1001 Router. At first I thought it was the stand-by unit but no it be the active unit and toggles between boxes if I trip failover. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Insteadofconfiguringonecontact,youcanspecifyanytochangetheseverityforallcontacts. Forexample,toenableallactionsforthealarminputcontact1,enterthefollowing: alarmfacilityinput-alarm1relay alarmfacilityinput-alarm1syslog alarmfacilityinput-alarm1notifiesAlarm Deletion. on my router-2, port 0 is inactive, port 1 is active. Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- TenGigabitEthernet0/0/0 May 18 2016 14:53:02 CRITICAL Physical Port Link Down [35] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1] GigabitEthernet0/1/1 May 11 2016 18:53:. Depending on the type of alarms you configure, you might see. The following example. Command Purpose Command Purpose 1. The following. Examples of Alarm Messages. Displaysallthealarmsthathavebeentriggered. show alarm-profile name —Displays the alarm profile configured for chassis. 1:2018, Clause 1. show cable modem voice. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. Shows the current configuration for each possible alarm. Depending on the type of alarms you configure, you might see. Bias-Free Language. Note: To clear the the alarm LED, you need to shutdown the ports which are not connected. show alarm. Step 7. show alarm settings. Displays the switch power status. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. Send power supply alarm traps to an SNMP server. The info keyword provides the same output as using no keyword. Examples. SNMP traps are generated when the inlet temperature sensor of the Cisco UBR-MC20X20V cable interface line card has a status change among normal, minor, major or critical. show facility-alarm status. Router# show facility-alarm status System Totals Critical: 4 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- Power Supply Module 1 Mar 12 2014 09:05:21 CRITICAL Power Supply Failure [0] xcvr container 0/0/0 Mar 12 2014. Severity levels are defined as the following: • 1—Critical. The State. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Router# show facility-alarm status critical System Totals Critical: 5 Major: 0 Minor: 0 Source Severity Description [Index] ----- ----- ----- Power Supply Bay 0 CRITICAL Power Supply/FAN Module Missing [0] GigabitEthernet0/0/0 INFO Physical Port Link Down [1] GigabitEthernet0/0/1 INFO Physical Port Link Down [1] GigabitEthernet0/0/2 INFO. Use the alarm facility power-supply global configuration command to associate the power supply alarm to the relay. show env {all | power | temperature} Displays the status of environmental facilities on the switch. You can limit the view by filtering on major or minor status. To view the alarms on Cisco ASR 900 Series Router, use the show facility-alarm status command. This example sets the secondary temperature alarm to the major relay, with a high temperature threshold value of 113 o F (45 o C). AlarmConfiguringandMonitoringGuide,CiscoIOSXE17(ASR920 SeriesRouters) FirstPublished:2020-07-31 LastModified:2023-03-23 AmericasHeadquarters CiscoSystems,Inc. 9. show facility-alarm status [critical | info | major] Displays generated alarms on. Effective from Cisco IOS XE Everest 16. showf~showipu •showfacility-alarm(3ページ) •showfailover(6ページ) •showfailoverdescriptor(21ページ) •showfailoverexec(22ページ)Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- subslot 0/0 May 18 2016 14:50:49 CRITICAL Active Card Removed OIR Alarm [0] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1] GigabitEthernet0/1/1 May 11 2016 18:53:36. 8. Step 7 . alarm facility power-supply syslog. show facility-alarm status [info | major | minor] ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. Title: Alarms for the Cisco ISA 3000Step 9 show facility-alarm status Displays all generated alarms for the switch. Verifying Normal Startup Sequence. alarm facility temperature {primaryshow facility-alarm status [info | major | minor] Shows information on all alarms that have been triggered. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. show env power. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. 10. Tologthealarms,youneedtoenabletheloggingalarm[critical|major|minor|informational]command attheglobalconfigurationmode. The following example shows how to use the show facility-alarm status command to verify if any critical alarm is generated when a module is removed from the system: Device# show facility-alarm status System Totals Critical: 8 Major: 0. Send power supply alarm traps to a syslog server. Router#show alarm Alarm contact 0: Description: External alarm contact on Motherboard Status: Not Asserted Application: Dry Severity: major Trigger: Open Mode: Input Router# Router#show facility-alarm status System Totals Critical: 0 Major: 1 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- External alarm contact Oct 16. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. The following example shows the output for the show facility-alarm status | inc Temp command. The following example. The example shows a critical alarm for Power supply along with the description: SPA Removed. 次に、 show facility-alarm status コマンドの出力例を示します。 Alarm LED が赤点灯した場合には "show facility-alarm status" コマンドを実行してどのような critical alarm が検知されているか確認し、必要な対処を行ってください。 例えば critical alarm は以下のように物理ポートがダウンしている場合にも検知されます。 Description. •show platform hardware slot P <0-5> mcu status •show facility-alarm statusCHAPTER 1 Cisco2x2RPDSoftware4. Examples of Alarm Messages. Step 7. Alarm Severity Alarmsarefilteredbasedontheseveritylevel. • Enter the clear facility-alarm command. show alarms / show facility-alarm status If your equipment has an alarm indicator, the above commands will show advise you what's alarmed & the reasoning. show alarm settings. show alarm settings. To view the posted temperature sensor alarms, use the show facility-alarm status command to show all the alarms in the system. Examples. show alarm settings. Facility Alarms provide a useful tool for operators to easily track and display the basic status of their equipment facilities. To clear a visual alarm, you must. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. show cable calls. Step 6. For the latest feature information and caveats, see the release notes for your platform and software release. Alarm Output Interface. For the latest feature information and caveats, see the release notes for your platform and software release. Thanks in Advanced. You can connect an external alarm, such as a buzzer or light, to the alarm output interface. Feature. You can verify the alarms that cause the LED to go red with the show facility-alarm status command. 7. router# show facility-alarm status | inc Temp Temp: Outlet P0/4 Apr 18 2016 13:05:12 INFO. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Step 2 alarm facility temperatureUse the command "show platform" €or €"show facility-alarm status" to determine status of Fans in the Tray. Description. alarm facility power-supply syslog. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored but the power supply state remains in OK state as the. Verifying Normal Startup Sequence. 11. show facility-alarm status . To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. The documentation set for this product strives to use bias-free language. Time-----Severity-----May 18 2016 14:50:49 CRITICAL. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. show facility-alarm. All alarms and events will be displayed in the order in which they were received. Command Purpose Step 1 configure terminal Enters global configuration mode. You cannot establish a console or Telnet connection to the system For information about troubleshooting Ethernet connections, see the “Troubleshooting Ethernet Connections” section on page 6-3. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. show alarm settings. Step 4 . For the latest feature information and caveats, see the release notes for your platform and software release. The following are examples of alarm messages that are sent to the console. end. show alarm profile [name] Displays all alarm profiles in the system or a specified profile. Managing Alarms Using the CLI. The LEDs indicate all system states in the startup sequence. Send power supply alarm traps to an SNMP server. Router(config)# logging alarm critical. Use the show env power command in privileged EXEC or user EXEC mode to display power information for the switch. Enter the show facility-alarm status command at the console. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. 1w release, if the link redundancy is enabled, show facility-alarm status will not report physical port link down on the interface unless both ports assigned to this interface are down, and transceiver missing on either port, active or standby, will be a critical alarm. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Router# show facility-alarm status System Totals Critical: 4 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- Power Supply Module 1 Mar 12 2014 09:05:21 CRITICAL Power Supply Failure [0] xcvr container 0/0/0 Mar 12 2014. To view alarms, use the show facility-alarm status command. 1g and 16. Title: Alarms for the Cisco ISA 3000alarm facility power-supply relay major. Step 6 . Verify the configuration. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. The example shows a critical alarm for Power supply along with the description: Router# show facility-alarm status System Totals Critical: 2 Major: 0 Minor: 1•show facility-alarm status [info |major |minor] AlarmsfortheCiscoISA3000 6 AlarmsfortheCiscoISA3000 MonitoringAlarms. 10.